DOGIPARK DOGIFOUNTAIN 7751 Manual de instalação e operação - Página 11

Procurar online ou descarregar pdf Manual de instalação e operação para Produtos para animais de estimação DOGIPARK DOGIFOUNTAIN 7751. DOGIPARK DOGIFOUNTAIN 7751 16 páginas. Pedestal dog drinking fountain

Pedestal Dog Drinking Fountain
7751 DOGIPARK DOGIFOuntAIn

Troubleshooting

I. InsufficientFlow
A. Ensure the service shut-off valve is fully open (provided by installer).
B. Ensure water supply is within the normal operating range of 40-60 psi.
1. If pressure is too low, flow can be drastically reduced.
2. If pressure is too high, the strainer and/or valve may have been damaged.
3. The unit is rated for a maximum range of 30-105 psi.
C. Inspect the unit's valve for damage, and replace if necessary.
D. Inspect the inline strainer for damage and/or clogging, and clean or replace as necessary.
E. Check all fittings and tubing for damage and leaks. Replace components as necessary.
II. Unit has problems draining
A. Remove any debris from the drain.
B. Remove any debris from the PVC pipe and fittings.
C. Check and clear the waste trap (provided by installer).