6.Safety Relay Tner-A31 Technical Parameters
Power supply
Power supply supply
Voltage tolerance
Power consumption
Output
Relay safety output
Transistor signal output
Relay contact capacity
AC-1
AC-15
DC-1
DC-13
Maximum switching
capacity
Contact resistance
Minimum load
Contact Material
General parameters
Output fuse (external)
Release the Response Time
Check resistance of input
tail
(Touch the edges / carpet)
Electrical life
Pollution level
Operating temperature
Working humidity
Impact-withstand voltage
Protection level
Storage temperature
Housing material
Installation mode
Dimensions
Weight:
Connection parameters
Range of cross-section
available for rigid
conductors
Range of cross-sections
available for flexible
conductors
Minimum conductor cross-
section
Maximum conductor cross-
section
Stritrip length
Minimum tightening torque
Maximum tightening
torque
Standard Application
Coniant
24V DC
+10%/-20%
2.9W
3NO + 1NC
<500mA 24VDC
6A/250VAC/1500VA
4A/240VAC
6A/24VDC/150W
4A/24VDC
12A(assigned on all security output contacts)
<100m Ω
10mA/5V
AgSnO2 + 0.2 µmAu
5A gL/gG
<30m s(, from input to output),
1kΩ ~10kΩ
80,000 times
2
-25℃~85℃
35% -85% (unfrozen or condensed)
2.5kV
Case IP30, terminal IP20, recommended for cabinet or housing IP54
-40℃~105℃
Flame-retardant PA66
Standard 35mmDIN guide rail / spring buckle
114.5mm×100.5mm×22.5mm
172g
0.5~2.5mm ²
0.5~2.5mm ²
AWG 24
AWG 12
8mm
0.5 Nm
0.6 Nm
EN 60947-1:2007/A2:2014 // EN 60947-5-1:2004/A1:2009
EN ISO 13849-1:2015 // EN 62061:2005 + A2:2015
13