Safety contact edge standard safety controller model: Tner-A31
A1: is connected to + 24V
A2: to 0V
Automatic reset:
Diial switch to A
Manual reset: Diial switch to M
(No resistance contact edge) Tner-A31 safety relay connection method:
Touch edge 1: Red and black lines: connect T1 and R1,
Touching edge 2: Red wire and black wire: connect to T2 and R2 in no particular order. If there
is no touch edge 2, it can be left unconnected.
± 10% (20V~26V)