Data Output (continued):
Output Data
Parameter
Tool
Tool Name
OK/NOK
Result
Count
Batch
Rolling Count
Total
Time
Date
EE Write Time
EE Write Date
Torque
Min Torque
Max Torque
Units
Angle
Min Angle
Max Angle
Tool Type A
Tool Type B
Tool Type C
Tool Type D
Tool Type E
Tool Type F
Tool Type G
Tool Type H
.
Description
ASCII character representing current parameter. Possible values
A' (0x41) through 'H' (0x48).
Type Three ASCII characters describing the tool type. Possible values
include 'DIG', 'CLK', 'AIR', and/or 'BAT'
Up to 8 alpha-numeric ASCII characters that represent a user defined
tool name.
Single character giving status of last fastening. 'O' (0x4F) for okay or 'N'
(0x4E) for not okay.
Single character giving status of last fastening. 'C' (0x43) for cycle,
'B'(0x42) for batch and 'R' (0x52) for reject.
Number of fasteners completed towards the batch. Possible values 0x00
through 0xFF.
Value representing the number of fasteners in a batch. Possible values
0x00 through 0xFF.
Integer (2 bytes) holding a rolling count. The count will increase with
each new result. Possible value 0x0000 through 0xFFFF.
Integer (2 bytes) representing number of batches completed in a given
parameter. Possible value 0x0000 through 0xFFFF.
6 ASCII bytes describing the time an event occurred in HHMMSS
format.
6 ASCII bytes describing the date an event occurred in MMDDYY
format.
6 ASCII bytes describing the last time the eeprom was written to in
HHMMSS format.
6 ASCII bytes describing the last date the eeprom was written to in
MMDDYY format.
6 ASCII numbers and/or decimal point representing the torque value
from the last fastening (if available).
6 ASCII numbers and/or decimal point representing the min torque
setting from the last fastening (if available).
6 ASCII numbers and/or decimal point representing the max torque
setting from the last fastening (if available).
Single character describing torque units used during last fasting.
Possible values 'I'/InLB, 'N'/Nm, 'F/FtLb, 'K'/KgCm, and 'm'/mKg.
5 ASCII numerals representing angle.
5 ASCII numerals representing min angle setting.
5 ASCII numerals representing max angle setting.
Three ASCII characters describing the tool type in parameter A.
Three ASCII characters describing the tool type in parameter B.
Three ASCII characters describing the tool type in parameter C.
Three ASCII characters describing the tool type in parameter D.
Three ASCII characters describing the tool type in parameter E.
Three ASCII characters describing the tool type in parameter F.
Three ASCII characters describing the tool type in parameter G.
Three ASCII characters describing the tool type in parameter H.