CYP CMSDI-84 Manual de operação - Página 11
Procurar online ou descarregar pdf Manual de operação para Comutador de matriz CYP CMSDI-84. CYP CMSDI-84 16 páginas. 16 by 4 / 12 by 4 / 8 by 4 / 4 by 4 3g-sdi matrix
6.4 RS-232 Pin Assignment
Pins definition of modem cable
CMSDI-44/84/124/164
PIN
1
2
3
4
5
6
7
8
9
Baud Rate: 19200 bps
Data bit: 8-bit
Parity: None
Stop bit: 1-bit
Flow Control: None
6.5 RS-232 Commands
Command
poweron
poweroff
portx xx
For example, when SDI output A needs to be SDI input 2, the
command would be porta 02.
Note: All the RS-232 command will be not executed unless followed
with a carriage return.
Commands are not case-sensitive.
Definition
NC
TxD
RxD
NC
GND
NC
NC
NC
NC
Description
Power ON
Power OFF
x= a~d output, xx=01~16 input
Remote Controller
PIN
1
2
3
4
5
6
7
8
9
Definition
NC
RxD
TxD
NC
GND
NC
NC
NC
NC