6 Maintenance
It is important to keep the light-sensitive area of the sensor free of dust to ensure correct measurements.
See Figure 1.
Clean the sensor with water and a brush without using:
• High-pressure cleaner
• Highly compressed air
• Solvents
• Corrosive/caustic agents
• Alcohol-based disinfectants
Do not bend the sensor as this would inflict permanent damage on the electronics of the sensor.
DOL 16 0-50/1000 LUX 0-10V
During cleaning and disinfection, the sensor should be removed and the sealing
plug for the cable should be mounted.
Alternatively, the sensor protective cap can be mounted. The sensor must be
placed with the light sensitive area of the sensor upwards during disinfection.