Ashcroft ZT12 Manual de instruções de instalação e manutenção - Página 2
Procurar online ou descarregar pdf Manual de instruções de instalação e manutenção para Transmissor Ashcroft ZT12. Ashcroft ZT12 7 páginas. High purity transmitter
Installation and Maintenance Instructions
for ZT12 High Purity Transmitter
1. INTRODUCTION
Please double-check the specifications for the model that you
have received.
If specifications such as the pressure range, power source,
or output are incorrect, accidents can occur. Please be sure
to use a model that is appropriate for your specifications, in a
location which is appropriate for your usage environment, and
which has been correctly wired and installed.
2. ATTENTION
Ashcroft shall have no liability for failure, product issue, or
physical injury resulting from the following:
• Modification and repair performed by any non-Ashcoft
personnel.
• Product issue caused by product of another company
• Misuse of product instructions, instrument operation and/
or not observing conditons/methods stipulated within the
instruction manual.
• Natural disasters, such as fire, seismic activity, water/flood
damage, lightning, etc.
3. GENERAL DESCRIPTION
This pressure transmitter is developed for the semiconductor
industry. In contrast to conventional transmitters, this product
offers a compact and lightweight design. Pressure is converted
into electric signals and transmitted by the sensing portion
equipped with strain gauges and a built-in electronic circuit.
ZT12
RANGE
: – 0.1~20 MPa
POWER
: 10~30 Vdc
OUTPUT
: 4~20 mA dc
(0.25)
EP
Notes:
Red Die Line Does Not Print
Ink: PMS 360
Printing Stock: Pressure Sensitive Aluminized Mylar
File Name: ZT12- Label_RevA_04-13-22_Dim_Dwg
ZT12- Label _W-UK_RevB_10-11-22_Dim_Dwg
© Ashcroft Inc. 2022, 250 East Main Street, Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0357, www.ashcroft.com
All sales subject to standard terms and conditions of sale. ZT12_Transducer_I&M011-10307_RevA_11-16-22
DATE
:11.2022
No.
:1234567
62 mm
4. OUTLINE DRAWINGS: MVT -
¼ VCR
) Male Flow Through
®
.18
[4.5]
Ø 1.00
[25.4]
Ø 0.79
.50
[20]
[12.6]
0.32
8.2
2.63
[66.8]
1.86
[47.2]
.39
.79
[10]
[20]
2XM3
OUTLINE DRAWINGS: FVS -
¼ VCR
) Female Swivel
®
Ø 1.00
[25.4]
0.50
[12.6]
0.32
[8.2]
1.86
3.55
[47.2]
[90.1]
2.74
[69.5]
0.76
[19.2]
Ø .79
[20]
⁄
-18 UNF (compatible with
9
16
M12X1 - 4 PIN
ELECTRICAL
TERMINATION
⁄
-18 UNF
9
16
(compatible with ¼ VCR
Male Flow Through (MVT)
.87
[22]
2.13
[54]
.197 [5]
.59
[15]
.59
[15]
⁄
-18 UNF (compatible with
9
16
0.18
[4.5]
M12X1 - 4 PIN
ELECTRICAL
TERMINATION
⁄
-18 UNF
9
16
(compatible with ¼ VCR
Female Swivel (FVS)
)
®
)
®
2