7. Operation Controls and Functions
The following sections describe the hardware components of the unit with
installation and functionality.
7.1 Front Panel
① HDMI/DVI indicators: When LED illuminate this means the input source
is with HDMI content and when the input source is DVI the LED will not
illuminate.
② HDCP indicators: When the input source is with the HDCP protection the
HDCP LED will illuminate.
③ SYNC Indicator: The LED will illuminate when the device detected source's
signal.
④ Output LED1~8: The LED will illuminate when output display is connected
with power on.
⑤ Power LED: The LED will illuminate when power is on.
7.2 Rear Panel
①② ③ ④ ⑤ ⑥
① IR IN: This slot is to connect with the IR receiver cable included in the
package and use the existing source ' s remote controls to control source
equipments.
② IR OUT: This slot is to connect with the IR blaster cable included in the
package and place it in front of the sources for infrared signal sending.
③ EDID Control Switcher: Switch the EDID between STD & TV. Switch to STD
to use built-in EDID or switch to TV to use TV ' s EDID. Default factory setting
is on TV, leave as it is when picture is displayed properly.
Note:
1. When EDID switch to TV, the unit will detect the first HDMI output
sink ' s EDID and record in the unit. If the first detected output sink is DVI
it will pass to next source until the first HDMI source been detected. The
detection priority is HDMI v1.3 > HDMI v1.2 > DVI.
① ② ③
⑦
4
④
⑤
⑧