Ashland PS50 Manual de operação, desempenho e especificações - Página 6
Procurar online ou descarregar pdf Manual de operação, desempenho e especificações para Bomba de água Ashland PS50. Ashland PS50 18 páginas. Anodized aluminum sump pump
Always disconnect the pump from the electrical power source before handling. If the system fails
WARNING
to operate properly, carefully read instructions and perform maintenance recommendations. If
operating problems persist, the following chart may be of assistance in identifying and correcting them.
SYMPTOM
Pump runs but does
not pump liquid
Thermal overload trips
Circuit breaker trips
Sump Pumps
Model: PS Series
Trouble Shooting
POSSIBLE CAUSES
1. Pump impeller maybe air locked
2. Vent hole clogged
3. Clogged inlet
4. Discharge shut off valve may be closed
5. Discharge check valve may be clogged
or have a broken clapper
6. Discharge head may be too high
1. Impeller may be clogged
with foreign objects
1. Excessive load possibly caused by a
short in the motor
2. If this condition happens after an
electrical storm, motor or control box
may be damaged by lightning
P
H o n e s t , P r o f e s s i o n a l , D e p e n d a b l e
1899 Cottage Street, Ashland, Ohio 44805
Telephone: 855 281-6830 • Fax: 877 326-1994
ashlandpump.com
U
M
P
6
CORRECTIVE ACTION
1. Purge air
2. Clean out the vent hole
3. Clean out the grinder inlet
4. Open gate valve
5. Remove and examine check
valve for proper installation and
freedom of operation
6. Check elevation
1. Check impeller for
freedom of operation, security
and condition. Clean impeller
cavity and inlet of any
obstruction
1. Contact qualified technician
2. Reset breaker.
If breaker trips again in a few
seconds check motor for
lightning damage
PS33/50 OM-rev04/2016