Cypress OSM-1000-BRD Manual de início rápido - Página 2
Procurar online ou descarregar pdf Manual de início rápido para Conversor de multimédia Cypress OSM-1000-BRD. Cypress OSM-1000-BRD 2 páginas. Osdp-wiegand converter
Também para Cypress OSM-1000-BRD: Manual de início rápido (2 páginas), Manual de início rápido (2 páginas)
Wiegand
Access
Control Panel
Ground
Data 0
Data 1
LED Out
Beeper Out
12VDC
Power
Supply
Power
Ground
Wiegand
Card
Reader
Power
Ground
Data 0
Data 1
LED IN
Status LED Behavior:
The OSM-1000-BRD unit has a tri-color LED that can display red, green, blue, and white. The startup sequence lasts approximately
5 seconds and the LED will display red, blue, green, white or display red, green, blue, white.
ACU Mode:
Communication with PD: the status LED will be blue with fast, green flashes or green with fast, blue flashes. The status LED will
briefly turn red when it receives reader data from the PD.
No Communication with PD: the status LED will be blue with slow, green flashes or green with slow, blue flashes. The status LED
will briefly turn red when it receives reader data from the PD.
PD Mode:
Communication with ACU: the status LED will red with fast, blue flashes or red with fast, green flashes.
No communication with ACU: the status LED will slowly fade from red to off, and back to red.
Bench Testing:
Bench testing is recommended to avoid troubleshooting issues in the field.
ACU Mode:
1.
At the bench, connect the OSM unit to the PD and the Wiegand access controller by following the ACU Mode Wiring Diagram.
2.
Observe the OSM unit and PD communicating. Refer to the "Status LED Behavior" section to verify that the OSM unit is
communicating with the PD.
3.
If the devices do not communicate, make sure the the baud rate and polling ID match. In the OSDP spec, the default baud rate
is 9600 and the default polling ID is 0.
PD Mode:
1.
At the bench, connect the OSM unit to the Wiegand reader and ACU by following the PD Mode Wiring Diagram.
2.
Observe the OSM unit and ACU communicating. Refer to the "Status LED Behavior" section to verify that the OSM unit is
communicating with the ACU.
3.
If the devices do not communicate, make sure the the baud rate and polling ID match. In the OSDP spec, the default baud rate
is 9600 and the default polling ID is 0.
ACU Mode Wiring Diagram
12VDC
Power
Supply
Power
Ground
8 - 16 VDC Input
Ground
Data 0
Data 1
LED I/O
Ground
Output Control
Buzzer
PD Mode Wiring Diagram
8 - 16 VDC Input
Ground
Data 0
Data 1
LED I/O
Ground
Digital Input
Digital Input
12VDC
Power
Supply
RS485 A
RS485 B
Ground
Strike N.O.
Strike COM
Strike N.C.
Ground
8 - 16 VDC Input
RS485 A
RS485 B
Ground
Strike N.O.
Strike COM
Strike N.C.
Ground
8 - 16 VDC Input
Power
Ground
OSDP Access
Control Panel
RS485 A
RS485 B
OSDP
Card
Reader
Power
Ground
RS485 A
RS485 B