BENCH TEST UNITS - Additional configuration information
With the units a the rapid polling (Setup/Config) mode, the Amber com LED can be used to determine
whether the units are in communication with each other.
Further Bench testing:
If the reader and panel are conveniently located, it is advisable to connect the reader to the Remote unit,
and the panel to the Central unit and test the units as a complete system. Use a test badge that has been
programmed into the panel to test operation. See the DPX-7000 manual for electrical connections and
further explanation of connecting readers and panels to the Duprex units.
Remember to disconnect any power supplies if you will be using the panel power supply or other
auxiliary supply. Only one power supply should be used for each unit.
Connect the Central unit to the Access Control Panel (ACP)
Connect the reader to the Remote unit.
Provide power to both units and verify communication.
Use a test badge to verify operation of panel, reader, and connections.
Doing the setup and initial testing with both the Central and Remote units when they are close together will
save time if there are any problems that need to be corrected or installation issues that need to be clarified.
Once the connection, setup, and configuration have been completed with both units, field installation and
final commissioning can be done.