3.
Set the baud rate to 115200 in the drop down menu and click disconnected above the green arrow to connect.
4.
Once the terminal is connected, press the space bar on PC keyboard and the welcome message will display. The test
application will automatically run the subclock test and report the results. The space bar is used as the input for the
USB test.
5.
To run each of the tests enter the letter next to the test description and follow the prompts. For example: p <enter>
will test the potentiometer (R11). The application will prompt the user for a sequence of rotations of the potentiometer,
and report the test result.
FM4-U120-9B560 Quick Start Guide, Doc. No. 002-05534 Rev. *A
Run PCB Board Test Demonstration
9