Technical Specification

1.5
1.5.1 Absolute Maximum
Ratings
Operating temperature
Storage temperature
Active USB current
All input voltages to signal
ground
All output voltages to
signal ground
ESD immunity
Electric Field Immunity
Table 2: Absolute Maximum Ratings
1.5.2 Operating
Specifications
Minimum data rate
Maximum data rate
Input Treshold Low RS-232
Input Treshold High RS-232
Output voltage Swing
Short-circuit tolerance
Short-circuit current
min. 0 °C
max. +70 °C
min. -55 °C
max. +85 °C
max. 100 mA
±25 V
±13 V
±8 kV contact HBM
±6 kV air HBM
±15 kV Human Body Model
3 V / m
300 Baud
220 kBaud guaranteed,
500 kBaud typically
min. 0.8 V, typ. 1.5 V
max. 2.4 V, typ. 1.8 V
1
min. ±5 V, typ. ±5.4 V
No limit
maximum ±60 mA
Operating system
Windows
Linux 1.5.0 32/64-bit
MAC OS 10 32/64-bit
Windows CE
RS-232
full implementation
RS-232 connector
DB9
USB 1.1 a 2.0 compatibility
yes, 12 Mbps (Full Speed)
USB connector
A type
Length of USB cable
1 m
Transmit indicator
red LED
Receive indicator
green LED
Table 3: Operating Range
1
Outputs Loaded with 3 kΩ.
2
Windows 8, Windows 7, Windows Server,
Windows Server 2003, Windows Vista, Windows XP.
Compatible with 32/64 bit. version.
3
Windows Mobile 2003, Windows Mobile 2003 SE,
Windows Mobile 5, Windows Mobile 6,
Windows Mobile 6.1,Windows Mobile 6.5
2
32/ 64-bit
3
Page 6