AMBIC EasiDoser Manual de Instruções - Página 8

Procurar online ou descarregar pdf Manual de Instruções para Equipamento agrícola AMBIC EasiDoser. AMBIC EasiDoser 16 páginas.

EasiDoser™ – Basic Menu Option Displays
EasiDoser™ – Set Two Pump Operations
Action
Press  Button twice
Correct PIN code entered
From Display 6
Press  Button once
From Display 7
Press  Button once
From Display 8
Press  Button once
From Display 9
Press  Button once
From Display 10
Press  Button once
From Display 11
Press  Button once
From Display 12
Press  Button once
From Display 13
Press  Button once
Ambic Equipment Ltd – EasiDoser™ Operating Notes
Display
Display Number 5
Enter PIN Code
_
Display Number 6
Number of Pumps
= 2
Display Number 7
Pump Types
12Volt
Display Number 8
Pump 1 Mode
Manual Mode
Display Number 9
Pump 1 Duration
00:15
Display Number 10
Pump 1 Start
Delay = 5s
Display Number 11
Pump 1 Inhibit
00:00
Display Number 12
Pump 1 Speed
= 80%
Display Number 13
Conductivity
Pump1 OFF
Display Number 14
Pump 1 Float
N/Open
Enter the current PIN Code by pressing the
buttons (in sequence):-
(default factory PIN =     )
Press   buttons to change the number of
←↓→
pumps fitted.
Press   buttons until correct voltage &
←↑↓→
pump type displayed.
Press   buttons until correct pump mode
for Pump 1 is displayed. (Manual, Signal or
←↑↓→
Direct)
Press   buttons until correct pump
duration (run time) is displayed. Run time can
←↑↓→
be set from 00:00 seconds to 05:00 minutes.
Default setting: 00:15
Press   buttons until correct pump Start
Delay is displayed. Pump start delay time can
←↑↓→
be set from 1 second to 60 seconds.
Default setting: 5s
Press
duration (run time) is displayed. Pump inhibit
time can be set from:
←↑↓→
00:00 seconds to 30:00 minutes.
Default setting: 00:00
Press   buttons until correct pump Start
Delay is displayed. Pump speed can be set
←↑↓→
from 40% to 100%
Default setting: 80%
Press   buttons until correct conductivity
is set. Available settings are from
←↑↓→
0.5mS to 9mS.
Default setting: OFF
Press   buttons until correct Float Switch
is displayed.
←↑↓→
Default setting: N/Open
-8-
Comment /Action
  buttons until correct pump
ADE7500 v1.3 (16/03/18)