5. Make sure the connections on the peristaltic pumps are tight
If the connections are not tight, there is a risk that the connections will leak air and compromise the
performance of the pumps when dispensing chemical. Ensure that no strain is put on the
connections - especially when the chemical container is being changed.
6. Check the hanger assemblies
Ensure that the non-return valves and filters are installed in the correct orientation/position.
7. Adjust the air
The air regulator can be adjusted up and down to vary the 'wetness' of the foam to suit the chemical
or for user preference (see main user manual for adjusting the liquid pressure switch).
8. Sleep Timer
To conserve power the EasiFoamer™ unit is fitted with a 'sleep function' that turns the unit off after
a set period of no activity. This is set to 30 minutes by default (see main user manual for adjusting
this parameter).
9. Make sure you are using a compatible chemical
•
Do NOT use barrier dips suitable only for dipping applications;
•
Use a chemical specially formulated for foaming applications;
•
Use a 2 pump model for applications using 2 part chemicals such as Chlorine Dioxide.
Install non-return
valves on air and
chemical lines
Install filters before
each chemical non-
return valve only