Ambient Technologies RCSTE Manual de instruções de instalação e funcionamento - Página 6
Procurar online ou descarregar pdf Manual de instruções de instalação e funcionamento para Controlo remoto Ambient Technologies RCSTE. Ambient Technologies RCSTE 7 páginas. Thermostatic on/off remote control – 120vac
Receiver
Slide Switch
1.
ON position: the system will remain on until the slide switch is placed in the OFF or RS position.
2.
RS position: the system will only operate if the remote receiver receives a signal from the transmitter.
3.
OFF position, the system is off. The slide switch should be placed in the OFF position if you will be
away for an extended period of time. If the remote receiver is mounted out of children's reach, the OFF
position also functions as a safety device by both turning the system off and rendering the receiver
inoperable.
1.
Light your gas appliance following the appliance lighting instructions that come with the appliance.
Confirm that the pilot light is on; it must be in operation for the remote control to operate the main gas
valve. Appliance pilot control knob must be in the ON position. Appliance ON/OFF switch must be in
OFF position.
2.
Slide the 3 position button on the remote receiver to the ON position. The main gas flame should ignite.
3.
Slide the button to OFF. The flame should extinguish (the pilot light will remain on).
4.
Slide the button to RS (the center position), then press the transmitter to turn the system to ON. The main
f i r e - p a r t s . c o m
gas flame should ignite.
5.
Press the transmitter to turn the system to OFF. The flame should extinguish (the pilot light will remain
on).
Symptom
1. Low battery icon on
display on transmitter.
2. Display is blank
3. Display shows "funny"
display
4. Appliance does not
come on.
5. Receiver cannot detect
signal.
50D0104 RCSTE Rel 0 Feb 10 2006
TESTING YOUR NEW REMOTE CONTROL SYSTEM
TROUBLESHOOTING
Causes
1. Low Battery on Transmitter
1. Wiring / Electrical Connections
2. Privacy (DIP) switch setting on
transmitter does not match receiver
3. Transmitter measures temperature
exceeding 99 degrees Fahrenheit
and shows "HI" on LCD display
4. Distance between the transmitter
and receiver is more than 20 feet
1. Receiver is installed in an
enclosure
2. 120VAC is not connected
1. Replace batteries. Change batteries every 6
months.
2. Check battery installation and replace
batteries.
3. Press Reset button at the back of the
transmitter.
1. Slide the switch to ON, if appliance comes
ON, wiring is not the cause.
2. If appliance does not come on, check wiring
connections.
3. Check to make sure the receiver is plug
into 120 VAC outlets.
1. Make sure the transmitter and receiver have
the same DIP switch settings.
1. Move transmitter to a cooler place and wait
until temperature drops below 99 degree.
1. Make sure the operating distance is less
than 20 feet
1. Make sure the receiver is not located inside
to the tight of an enclosure.
2. Connect receiver adaptor to 120VAC
power supply.
Page 6 of 7
Action
Ambient Technologies
A Division Of Monessen Hearth Systems