4. Replacing Parts.
4.1 Replacing the lamp - general
It is very important that your replacement
lamp is exactly the same as the one it was
supplied with. Failure to fit the exact same
type could cause the heater to fail or even
become dangerous especially when used in
an outdoor environment.
Please contact AmbiRad to purchase your
replacement lamp and state the model
number of the heater you wish to fit the
lamp to.
Your new lamp should not be handled with
bare hands.
Remove finger marks with a soft cloth and
methylated spirits or alcohol. Finger marks
will burn into quartz causing premature
lamp failure.
If you are in any doubt about following the
procedure below, please contact us for
technical assistance. The mains power
should be disconnected before any attempts
are made to replace the lamp. The following
should be carried out with compliance to the
latest IEE regulations. If you are unfamiliar
with installing such fixtures, contact a
qualified electrician to carry out.
4.2 Apollo range:
1. Disconnect from the power supply and
remove the heater from wall fixings before
attempting to replace any lamp.
2. Remove the guard by flexing one end.
3.
Remove
the
extrusion(s) and fascia panels (fitted between
lamps on large models) adjacent to the failed
lamp (see below).
screws
from
the
4. Remove the panels to expose the lamp
connections (see below).
5. Disconnect lamp leads from terminal plates,
and remove lamp retaining clips (see diagram
below).
6. Slide the lamp out through the extrusion.
7. Fit a new lamp, taking care not to mark the
end
reflector or handle the lamp (see caution note).
8. Replace lamp retaining clips and connect the
new lamp leads to the terminal plates, ensuring
live/neutral leads are also reconnected.
9. Replace the end extrusion(s) and fascia
panels securely, using the fixings previously
removed and refit the guard.
Caution. Do not handle lamp with bare hands.
Remove finger marks with a soft cloth and
methylated spirit or alcohol. Finger marks will
burn into quartz causing premature lamp failure.
Please note: Apollo outer casing can reach
high temperatures.