ACR Electronics Tenbury T550DA/ECO Руководство по эксплуатации - Страница 9
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Плита ACR Electronics Tenbury T550DA/ECO. ACR Electronics Tenbury T550DA/ECO 17 страниц.
CURRENT June 2018 Tenbury T5500 install manual 1217-1.pdf
mild weather with smokeless fuel. Under
certain weather circumstances e.g. fog
the chimney will not draw su ciently
and could cause asphyxiation. Either
await better weather conditions or burn
wood only.
In the rare event of a malfunction due to
overheating or a chimney re, the air
slides should be shut down completely
and the fuel allowed to burn out. In the
event of a chimney re, once the air
slides have been closed completely, dial
999 for assistance. If the appliance has
overheated, the appliance and ue will
need to be inspected for any damage
before it can be operated again.
Recommended Fuels
Wood : hardwood such as ash, oak and
C
beech which have been cut for at least 2
years and stored under shelter. The logs
M
should have a maximum moisture
Y
content of 20%. Maximum log length
400mm, maximum width 125mm.
CM
Smokeless Fuels
MY
Petroleum coke content such as
CY
Anthracite, Phurnacite, Maxibrite
CMY
suitable for use with a closed heating
appliance.
K
Instructions for use with wood
• Open the secondary air slider to the
left hand side of the door, and open
the primary air slider to the right hand
side of the door by fully pushing the
levers inwards.
• Lay relighters or rolled up
newspapers on the grate and add a
small amount of kindling wood to the
top. Place 1 or 2 small logs on the
top.
• Light the newspaper or relighters
using a long taper and push the door
closed but do not engage the locking
handle fully.
• When the re is burning ercely, after a
couple of minutes add more logs and
: below 20%
9
08/04/2019
Prohibited Fuels
Green wood : i.e wood which is less
than 2 years old with a moisture content
of above 20%
Recovered wood: i.e pallets, railway
sleepers, painted/treated wood etc.
These will have been chemically
treated and will pollute the atmosphere
and possibly overheat the appliance.
Housecoal / Bituminous coal/Petroleum
Based Coke: over 20% - this will overheat
the appliance and possibly damage the
unit and craze the glass. Slumbering the
stove with this fuel would also damage the
ue liner
Para n re lighter blocks : these can
cause damage to the glass of your
appliance.
Liquid fuels
Always check with your dealer or
directly with the manufacturer as
using the incorrect fuel may
invalidate your guarantee and
damage your appliance.
close the door.
• When the re has become established,
close the primary air, to the right hand
side of the door, by pulling the lever
fully outwards.
• The burning rate can be altered by
moving the secondary air slider, to the
left hand side of the door - pull the
lever outwards to close down and
push the lever inwards to increase the
burn rate.
• Care should be taken to ensure that
the logs are not placed higher than the
log guard allows.
Instructions for use with
smokeless fuel
16:33:23