OPERATING PROCEDURES

IMPORTANT: Hook machine up to at least 115psi of air and connect battery clamps to
vehicle's battery before using.
SYSTEM FLUSH PROCEDURE:
1. Make sure vehicle is turned off.
2. Use suction wand to remove fluid from overflow bottle. (see "Suction Wand" procedure)
3. Remove radiator cap, and use suction wand to lower fluid level below the upper radiator
hose. Re-install cap.
4. Disconnect upper radiator hose.
5. Connect black service line to radiator.
6. Connect red service line toward block.
7. Use included hose clamps to pinch off all lines going to the overflow bottle.
8. Open ball valves on both hoses (it may be necessary to adjust the black ball valve slightly
to balance the exchange process).
9. Turn top dial to "Remove Fluid" position, and bottom dial to desired fluid type.
10. Turn vacuum switch & pump switch on to begin flush.
11. Turn both switches off when finished.
12. Disconnect service lines and repeat step 3.
13. Disconnect adapters and replace upper radiator hose.
14. Top off radiator and refill overflow. (see top-off procedure)
DRAIN & FILL PROCEDURE
1. Make sure vehicle is turned off.
2. Remove radiator cap.
3. Connect cone adapter to black service line & insert into radiator.
(use to service a cooling system component)