MAINTENANCE
NOTE: Proper handling and care will extend the life and service of the meter
Turbine Rotor
The meter is virtually maintenance-free. However, it is important the rotor moves freely.
Keep the meter clean and free of contaminants.
The rotor can be removed for cleaning and inspection. Begin by unscrewing the nose cone
from the outlet end of the meter. A 1/4" square socket extension can be used. Remove
the lock and flat thrust washers. Rotor can then be removed from shaft. Note orientation
because rotor is not bi-directional. Remove debris or deposits using soft brush or small
probe. Reassemble in reverse order.
10
1.800.561.8187
Blowing compressed air through the turbine assembly
could damage the rotor.
Do not allow liquids to dry inside the turbine.
Handle the rotor carefully. Small scratches or nicks can
affect accuracy.