INSTALLATION INSTRUCTIONS
The installation of the appliance must be in accordance
with the relevant requirements of the Gas Safety
(Installation and Use) Regulations 1984 (as amended),
Building Regulations and the Building Standards
(Scotland) (Consolidation) Regulations. It should be in
accordance also with any relevant requirements of the
local Gas Region and Local Authority, and the relevant
recommendations of the following current British Codes
of Practice & Standards:
BS. 6891: Installation of pipes and meters. Low pressure
installation pipes.
BS. 5440: Parts 1 Flues & Part 2 Air Supply
BS. 5871: Part 1 Installation of Gas Fires. Convector
Heaters, Fire/Back Boilers.
BS. 6461: Codes of Practice for factory-made insulated
chimneys for internal application.
BS. 8303: Solid fuel appliance flue system.
In your own interests and that of safety to comply with
the law all gas appliances should be installed by
competent persons (Corgi Registered) in accordance with
the above regulations and with these instructions. Failure
to install the appliance correctly could lead to prosecution.
THE LOCATION
To ensure adequate circulation of convected air it is
recommended that the stove should not be installed into
a recess of a depth any greater than 300mm.
The appliance must be installed on a base of
incombustible material, at least 12mm thick, extending to
at least the front of the stove supporting legs or level with
the supporting front legs when fitted in their alternative
position, and to 85mm beyond each side of the stove
(570mm). See fig. 1, 1a and 1b.
The hearth must be capable of withstanding a maximum
temperature of 150˚C. Conglomerate marble, marble and
tiled surrounds can meet this requirement.
REMOVAL OF COMBUSTIBLE
MATERIAL
Combustible material must be cleared from the area
shown in fig. 1.
If any opening larger than that shown in fig. 1a is to be
used, the opening size must be reduced using non
combustible material to bring it within the limits required
for closure plate mounting. It must be at least 380mm
wide and 400mm in height.
There must be a minimum distance of 215mm between
the sides of the stove and any combustible material.