Aktakom ACM-2031 Руководство пользователя - Страница 12
Просмотреть онлайн или скачать pdf Руководство пользователя для Измерительные приборы Aktakom ACM-2031. Aktakom ACM-2031 20 страниц. Ac/dc clamp meter
position. Push FUNC. button to select
3.The red lead should be connected to the anode
and the black lead to the cathode of the diode.
4.The typical voltage drop should be about 0.6V
for silicon diode or 0.3V for germanium diode.
5.If the diode is reverse biased or there is an
open circuit the reading displayed will be "OL".
CAPACITANCE MEASUREMENT
1. Insert the black and red test leads into the
COM andV:Hz
2.Set rotary switch at desired :
position. Push FUNC. button to select
3. Connect test leads across the capacitor under
measurement and be sure that the polarity of
connection is observed (Note: The polarity of the
red lead connection is positive "+").
4.Read the measure result directly from the
display.
MEASURING FREQUENCY
1. Insert the black and red test leads into the
COM andV:Hz
2.Set rotary switch at desired Hz position, Push
Hz/Duty button to select frequency mode and
connect the test lead tips in parallel with the
circuit to be measured. Be careful not to touch
any electrical conductors.
input terminals respectively.
input terminals respectively.
.
range
.