Aktakom AMM-1081 Руководство по эксплуатации - Страница 19

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Мультиметр Aktakom AMM-1081. Aktakom AMM-1081 20 страниц. Smart multimeter

6-2 Replacement of Fuse
Caution :
a. Fuse A -
To be protected the circuit from overload current
mA range ( 60 mA, 600 mA ).
b.Fuse B -
To be protected the circuit from overload current for
the " 10 A " range.
1)When the mA current range can not operation,
please check if the Fuse A is broken or not ?
2)When the 10 A current range can not operation,
please check if the Fuse B is broken or not ?
3)When replace the fuse should take the test leads from
the measuring circuit and power off the meter.
4)Take the screws away from the down case, loose the
housing case, the fuses are install on the fuse socket
on the PCB.
5)For safety consideration, when replace the fuse
according the spec. ( should use the approval fuse )
and reinstall the cover.
6)Make sure the housing case is secured with the screw
after replace the fuse.
When make the replacement,
should change the right
spec. fuse .
Rating : 630 mA
Rating : 10 A