Aktobis WDH-H3 Руководство по эксплуатации - Страница 9

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Очиститель воздуха Aktobis WDH-H3. Aktobis WDH-H3 12 страниц.

Aktobis WDH-H3 Руководство по эксплуатации
8.) Filter change / filter change indicator
The unit is equipped with a filter change indicator. Depending on the duration of use and the degree of soiling, this
may be signalled to you by the indicator panel flashing ! This is the time when the pre-filter should be cleaned
and/or the fine filters replaced.
Notes:
 Under normal conditions, the fine filters last for approx. 4,300 operating hours or up to 18 months with an
operation of approx. 8 hours per day ! In more polluted rooms, e.g. smokers' households, the filters may have
to be replaced after approx. 6 months (at the latest when the HEPA filter is dark brown, it should be replaced) !
 Disconnect the mains plug before cleaning/replacing the filters. For best filtration results, we strongly
recommend that you use only original filters from the manufacturer.
 Never wash the fine filters. (Only the pre-filter and the ESP filter can be cleaned).
To change the filter, follow the instructions and diagrams as described earlier in the operating instructions under
point 3.).
After the pre-filter has been cleaned and/or the fine filters have been replaced, it is necessary to reset the filter
change indicator. To do this, switch the air purifier on again and now press the On/Off button
approx. 3 seconds! The successful reset is signalled by a short acknowledgement tone. In addition, the flashing of
the display field will stop again.
Cleaning the ESP filter block:
The ESP filter block made of stainless steel can be cleaned as follows.
 Carefully pull the ESP filter block out of the drawer like a honeycomb (touch
the top and bottom).
 First remove the coarse dust and dirt with a hoover.
 Then brush the fins of the ESP filter block with a soft brush.
 Again, remove any loose dust and dirt with a hoover. Also remove any dust
residue from the drawer itself.
 Now rinse the ESP filter block in a sink with the help of washing-up liquid and
a soft brush (see illustration opposite).
 Allow the ESP filter block to dry completely.
 Finally, push the ESP filter block back into its drawer and close the filter
compartment door properly.
9.) Cleaning & Storage
Please always disconnect the mains plug first and allow the air purifier to drain completely before carrying out any
cleaning activities on your unit !
9.1 Cleaning:
 Use a soft and damp cloth to clean the outside of the unit.
 Only use mild cleaning agents to clean your air purifier.
 Please ensure that water does not get into the interior of the unit or the electrical display panel (display) at any
time !
9.2 Storage:
 We recommend covering the unit for storage or ideally packing it in its original box.
 Store the unit in a dry and sufficiently ventilated place/space.
Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
permanentlyfor