POSSIBLE cAUSE
SYMPTOM: Burners do not come on.
Unit is not connected to gas service
Pilot is not burning
Thermostat is set to very low temperature
SYMPTOM: Fryer does not reach selected temperature.
Unit may not have been operating long enough
Thermostat may be defective
Too little gas pressure, dirty gas line
SYMPTOM: General frying problems.
Temperature too low or too high
Thermostat out of calibration
!
WARNING
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
tROUBLESHOOtING GUIDE
Always disconnect the gas service before cleaning or
servicing the fryer.
Countertop Fryer
SUGGEStED ActION
Visually check unit is plumbed to gas
Light pilot
Set temperature to desired value
Unit preheats to 350ºF in about ten minutes
Unit will require service
Call for authorized service
Set unit to recommended temperature for foods being fried.
Unit will require service