American Safe Room ASR-200-AV-NBC Safe Cell Руководство по установке и эксплуатации - Страница 17
Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Очиститель воздуха American Safe Room ASR-200-AV-NBC Safe Cell. American Safe Room ASR-200-AV-NBC Safe Cell 19 страниц. Nuclear, biological, and chemical overpressure filter system
Specifications — standards
DOP Test
This has been the industry standard test method for many years. It is conducted using a forward
light scattering photometer. The HEPA is challenged with 0.3 micrometer particles of dioctyl-
phthalate (DOP). By measuring the upstream and downstream concentration of these particles, the
HEPA filter cell efficiency can be calculated.
Underwriters Laboratories Classification UL 586
This classification to insure that each HEPA filter cell is individually tested at the factory. Additionally,
representative HEPA filter cells are tested by UL to ensure that they provide their rated HEPA level
filtration, after being subjected to the following conditions of a high moisture environment of (90%
R.H.), a high temperature environment of (371 degrees Celsius), low temperature environment of
(-3 deg/C). UL also subjects the HEPA filter cell to a spot flame test of 954 degrees Fahrenheit.
Activated carbon filter for protection against war gases
The nuclear grade war gas adsorber is a block sieve filter cell consisting of two containment medias
and a block of nuclear grade war gas carbon.
It is effective in the removal of the following war gases:
Hydrogen cyanide
Phosgene
Mustard gas
Sarin
Ricin
VX
NUK-TK Nuclear Grade Carbon Specifications
Cell size
12 inches (304 mm) x 24 inches (608 mm) x 6 inches (152 mm) high.
Carbon, activated impregnated TEDA copper-zinc-molylebeunm-triethylenemelamine
1. ASTM D 2854-1996
2. ASTM D 2867-1999
3. ASTM D 3802-1997
4. ASTM D 3467
5. ASTM D 2862/D5158
6. ASTM D 3838
7. ASTM D 3466
8. ASTM D 3803
9. Impregnate
Standard test method for apparent density of activated carbon
Standard test method for moisture in activated carbon
Standard test method for ball-pan hardness of activated carbon
Activity for CCL: 60% minimum
Particle size: 4 x 8 Mesh U.S.
pH aqueous extract: 9.2 minimum
Ignition temperature 330 Celsius
Radioactive iodine removal
2.1 Potassium iodide, 3.1% TEDA
ASR-200-AV-NBC Safe Cell
Installation and Operation Manual
Revision C - April 27, 2016
Section
L
Page 17