Air & Allied Sales MP-35A Руководство по эксплуатации - Страница 9

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Инструменты Air & Allied Sales MP-35A. Air & Allied Sales MP-35A 11 страниц. Air nippers

●When there is an air leak from an air pin part in the state Where the lever is not pushed
(state which the valve switch of a nipple with a valve opened)
A urethane ball(⑱) needs to be exchanged.
・The exchange method of a urethane ball(⑱)
(1) Intercept an air source of supply.
(2) Remove an air hose from a main part. (Refer to Fig. 1)
(3) Remove screw(⑤) with a minus driver.
(4) Take out a spring (⑳) and urethane ball(⑱).
(5) Put in new urethane ball(⑱).
(6) Put in spring(⑳).
* Direction of a spring (urethane ball side: a smallness side, the screw side : a largeness side)
(7) Screw(⑤) is attached and it completes.
※For safe reservation, please close the valve switch of a nipple with a valve before performing the above-mentioned
maintenance.
●When there is an air leak from an air pin part in the state Where the lever is not pushed .
(state which closed the valve switch of a nipple with a valve)
(1) Request repair from a maker through the store for which it asks.
9/11
Air & Allied Sales (Pacific) Pty Ltd
www.air-allied.com.au