Barnes 3CDG5 Руководство по установке и эксплуатации - Страница 9
Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Водяной насос Barnes 3CDG5. Barnes 3CDG5 20 страниц. Diaphragm pumps
Также для Barnes 3CDG5: Руководство по установке и эксплуатации (18 страниц)
SECTION E: TROUBLE SHOOTING
If your pump does not prime or operate properly, check the following:
1.
Pump may be too high above or far from water.
2.
Leaks in suction hose or hose connection to pump. Check if hose inner lining has loosened. If loose,
pump suction will cause lining to collapse and block hose.
3.
Valves may not be seating properly due to accumulation of residue or wear.
Pour water in suction and discharge chambers to help seal valves.
4.
Check diaphragm for breaks or leaks
5.
Make sure that end of suction line is in position to allow water to enter; it may be buried in muck or
blocked in other ways.
SECTION: F REPLACEMENT PARTS
F-1 ORDERING REPLACEMENT PARTS:
When ordering replacement parts, ALWAYS furnish the following information:
1. Pump model number. (F-2)
2. Pump serial number.(F-3)
3. Part description.
4. Item part number.
5. Quantity required.
6. Shipping instructions.
7. Billing Instructions.
F-2 MODEL NUMBER:
This designation consist of numbers and letters which represents the discharge size, series horsepower, motor
phase and voltage, speed and pump design. This number is used for ordering and obtaining information.
F-3 SERIAL NUMBER:
The Serial Number block will consist of a six digit number, which is specific to each pump and may be preceded
by a alpha character, which indicates the plant location. This number will also be suffixed with a four digit
number, which indicates the date the unit was built (Date Code).
EXAMPLE: A012345 0490.
Reference the six digit portion (Serial Number) of this number when referring to the product.