For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance
with the wiring regulations, to provide a full disconnection under overvoltage category III
conditions (contact opening distance equal to or greater than 3mm).
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or
similarly qualified persons to avoid a hazard.
Do not obstruct the fan or exhaust grille to ensure optimum air passage.
ensure adequate air return into the room in compliance with existing regulations to ensure
proper device operation.
If the environment in which the product is installed also houses a fuel-operating device
(water heater, methane stove etc., that is not a "sealed chamber" type), it is essential to ensure
adequate air intake, to ensure good combustion and proper equipment operation.
Install the product so that the impeller is not accessible from the air outlet side as verified
by contact with the Test Finger (test probe "B" of the norm eN61032) in compliance with the
current safety regulations.
Ceiling Installation
To guarantee the IpX4 degree of protection against moisture in case of ceiling installation,
use the appropriate ceiling mount kit, which is not included. Use only the rear entry hole for
supply cables. If there is a possibility of condensation along the air discharge duct, provide a
drainage system to prevent condensation from discharging into the environment through the fan
Attention: do not mount the product on the ceiling without this kit.
Window Installation
In case of window installation, it is necessary to use the appropriate window kit, which is not
included. Attention: do not mount the product on the window without this kit.
1.1 Hazard Symbols
REFER TO INSTRUCTION MANUAL
read and understand the installation and maintenance manual before installing,
operating or maintaining this product.
1.2 Important Information
This manual contains important information on the safe and
appropriate assembly, transport, commissioning, operation,
maintenance, disassembly and simple troubleshooting of the product.
While the product has been manufactured according to the accepted
rules of current technology, there is still a danger of personal injury or
damage to equipment if the following general safety instructions and
the warnings contained in these instructions are not complied with.
Read these instructions completely and thoroughly before
working with the product.
Keep these instructions in a location where they are accessible
to all users at all times.
Always include the operating instructions when you pass the
product on to third parties.
671982 | SepTemBer 2021
1.3 Personal Protective Equipment
The following minimum personal protective equipment (ppe) is
recommended when interacting with this product:
Protective Steel Toed Shoes - when handling heavy objects.
Full Finger Gloves (Marigold PU800 or Equivalent) - when
handling sheet metal components.
Semi Fingerless Gloves (Marigold PU3000 3DO or Equivalent) -
when conducting light work on the unit requiring tactile dexterity.
Safety Glasses -
when conducting any cleaning/cutting operation
or exchanging filters.
Reusable Half Mask Respirators -
have been in contact with normal room or environmental air.
We would always recommend a site specific risk assessment by a
competent person to determine if any additional ppe is required.
when replacing filters which
pAGe 2