American Standard Savona Corner 2902.XXXW Series Инструкции по установке - Страница 2

Просмотреть онлайн или скачать pdf Инструкции по установке для Ванны American Standard Savona Corner 2902.XXXW Series. American Standard Savona Corner 2902.XXXW Series 4 страницы. High gloss acrylic shown less all fittings whirlpool

INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs
as required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an
access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for
access to the drain components.
1. Position the whirlpool into the installation opening and level the deck, shimming the integral support feet as necessary.
2. Install drain components to the whirlpool following the manufacturers instructions. Before replacing your whirlpool for final
installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing for
suggested opening size and location dimensions.
3 . Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet. Secure the shims
using construction adhesive, silicone, mortar or equivalent materials. While not a necessity, the use of a foundation base
consisting of cement (e.g. Sakrete), mortar, or grout will help provide a solid and secure installation.
LEVELING SURFACE
SUNKEN OR ISLAND
INSTALLATION
752460-100 REV. E
TYPICAL CORNER INSTALLATION
WATERPROOF
SEALANT
20-1/2"
(521 mm)
BATH
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED
56-3/4"
(1441 mm)
HEIGHT OF FRAMEWORK
INCLUDES PLYWOOD,
TILES,ETC.
SEE CUTOUT TEMPLATE PROVIDED
SPIC AND SPAN ® IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE
(2)
56-3/4"
(1441 mm)
FRONT OR SIDE
ACCESS PANEL
REQUIRED FOR
PUMP SERVICING.