Troubleshooting Guide

Guide de Dépannage
Problem
Possible Cause
Does not flush
a. Water supply valve closed.
b. Supply line blocked.
c. Flush valve chain too loose or disconnected.
d. Sand or debris lodged in water control.
Poor or
a. Bowl water level too low.
sluggish flush
b. Supply valve partly closed.
c. Partially clogged trapway and/or drain pipe
and/or vent.
d. Supply pressure too low.
Toilet leaks
a. Poor supply line connection.
b. Poor bowl to tank/floor connection.
Toilet does not
a. Flapper seal leaking or deformed.
shut off
b. Sand or debris lodged in water control.
c. Flush valve chain too tight, holding flapper open.
Toilet bowl
a. Wax ring not fully compressed.
rocks after
b. Floor not level.
installation
Problème
Cause/problème
L'eau ne
a. Alimentation de l'eau fermée.
chasse pas
b. Tuyau d'alimentation bloqué.
c. Chaîne du robinet de chasse d'eau desserrée ou
débranchée.
d. Sable ou débris logé dans le régulateur de débit d'eau.
Chasse faible
a. Niveau d'eau de la cuvette trop bas.
ou paresseuse
b. Robinet d'alimentation partiellement fermé.
c. Siphon ou tuyau de chute ou orifice bouché.
d. Pression d'eau à l'entrée trop faible.
Fuite de la
a. Mauvais raccordements des tuyaux d'alimentation.
toilette
b. Mauvaise installation de la cuvette sur le plancher.
L'eau ne
a. Le garde d'eau du clapet fuit ou est déformé.
s'arrête pas
b. Sable ou débris logé dans le régulateur de débit d'eau.
c. La chaîne de la chasse d'eau est trop serrée, en
tenant le clapet ouvert.
La cuvette
a. L'anneau de cire n'est pas bien comprimé.
bouge après
l'installation
b. Le plancher n'est pas de niveau.
See Step 8 For Diagram
Corrective Action
a. Open valve and allow water to fill tank.
b. Shut off water supply, disconnect supply line and inspect all gaskets
and washers. Reassemble.
c. Readjust chain length as required.
d. Shut off water supply. Remove cap and clean as per Fluidmaster
maintenance instructions at:
www.americanstandard-us.com/enews/fluidmasterguide.pdf
a. Check that refill tube is connected to water control and
inserted into overflow tube without being kinked or damaged.
b. Open supply valve fully. Be sure that proper supply tube size is used.
c. Remove obstruction. Consult a plumber if necessary.
d. Normal supply pressure must be at least 20 psi.
a. Review Step 7 of installation procedure.
b. Review Step 1 through 6 of installation procedure.
a. Clean debris from seal surface. Replace flapper seal as needed.
b. Shut off water supply. Remove cap and clean as per Fluidmaster
maintenance instructions at:
www.americanstandard-us.com/enews/fluidmasterguide.pdf
c. Readjust chain length as needed.
a. Retighten bowl-to-floor knobs.
b. Use toilet shims and /or place a bead of caulk around the base of the toilet.
Voir le schéma à l'étape 8
Mesure corrective
a. Ouvrir le robinet pour permettre à l'eau d'entrer dans le réservoir.
b. Fermer le robinet, débrancher le tuyau du réservoir et vérifier les joints et rondelles.
Réassembler le tout.
c. Ajuster la longueur de la chaîne si nécessaire.
d. Couper l'alimentation en eau. Enlever le capuchon et nettoyer selon les consignes
d'entretien de Fluidmaster au www.americanstandard-us.com/enews/fluidmasterguide.pdf
a. Vérifier que le tube de remplissage est raccordé au régulateur de débit d'eau et inséré
dans le tuyau de trop-plein sans être entortillé ou endommagé.
b. Ouvrir le robinet d'alimentation complètement. S'assurer aussi que la dimension des
tuyaux est appropriée.
c. Éliminer l'obstruction. Consulter un plombier, si nécessaire.
d. La pression devrait normalement atteindre au moins 20 lb/po2.
a. Revoir l'étape 7 pour la procédure d'installation.
b. Revoir les étapes 1 à 6 pour la procédure d'installation.
a. Nettoyer les débris de la surface du garde d'eau. Remplacer le clapet si nécessaire.
b. Couper l'alimentation en eau. Enlever le capuchon et nettoyer selon les consignes
d'entretien de Fluidmaster au www.americanstandard-us.com/enews/fluidmasterguide.pdf
c. Ajuster la longueur de la chaîne si nécessaire.
a. Resserrer les boutons fixant la cuvette au plancher.
b. Utiliser les cales de toilette et/ou mettre une petite quantité de mastic isolant autour de la
base de la toilette.
7