Environmental conditions
• Operating temperature: - 5 ... + 45°C
• Storage temperature: - 25 ... + 55°C
• Transport temperature: - 25 ... + 70°C
• Relative humidity: 95% not condensing
Switching, display and connection elements
The device is equipped with a programming pushbutton
and a programming LED, membrane pushbuttons, LED
for status indication and terminals for connecting the KNX
bus line and the inputs.
Switching elements
• Pushbutton (3) for switching between the normal and
programming operating mode
• Pushbutton (6) for switching between the operating mo-
des: forced (pushbuttons on the front panel: active) or
automatic (pushbuttons on the front panel: not active)
• Pushbuttons (2) for forced operation of the input con-
nections
Switching to the forced operation mode allows to simulate
the state of the inputs with the pushbuttons on the front
panel of the device; in this way it is possible to test the
correct operation of the coordinated loads before connec-
ting any device to the input terminal blocks.
Display elements
• Red LED (4) for displaying the active operating mode of
the device (on = programming, off = normal operation)
• Green LEDs (8) for displaying the switching status of
the input channels (on = closed contact, off = opened
contact)
• Red LED (7) for displaying the operating mode (on =
forced operation, off = automatic operation)
1A
2A
1
2
3
1
1B
2B
9
10
11
2
1A
2A
1B
2B
3
EK-CA1-TP
8xD.I. Dry Contacts
4
5
bus KNX
1) Terminal blocks for inputs
2) Pushbuttons for forced operation of the inputs
3) Programming pushbutton
4) Programming LED
5) Terminal block for KNX bus line
6) Pushbutton for toggling between manual and automatic operation
7) LED for indication forced / automatic operation mode
8) LED for status indication of the inputs
i
Note. In case of failure of bus voltage, the control of
the loads is not possible with the devices connected
to the binary input. It is still possible if the coordina-
ted KNX actuators are equipped with pushbuttons
or other control manual devices and is present the
mains voltage 230 Vac.
3A
4A
4
5
6
7
8
3B
4B
12
13
14
15
16
8
3A
4A
3B
4B
7
6
Mounting
The device has degree of protection IP20, and is there-
fore suitable for use in dry interior rooms. The housing is
made for rail mounting according to EN 60715 in boards
or cabinets for electrical distribution. The installation is in
horizontal position, the correct position is when the KNX
bus terminal is located at the bottom and the terminals for
the inputs are located at the top. For the installation of the
device on the rail proceed as follows:
• with the aid of a tool bring the locking device in the fully
lowered position (1);
• place the upper edge of the rear inner profile on the
upper edge of the rail (2);
• rotate the device towards the rail (3);
• push the locking device upward until it stops (4).
Before removing the device, be sure the inputs have been
disconnected and the bus terminal has been extracted
from its slot. Use a screwdriver to slide down the locking
device and remove the device from the rail.
1
3
i
Note. It is recommended that the installation of the
device always ensure the full accessibility of the
front side to allow the operation of the membrane
pushbuttons.
Connection of the KNX bus line
The connection of the KNX bus line is made with the ter-
minal block (black/red) included in delivery and inserted
into the slot of the housing.
Characteristics of the KNX terminal block
• spring clamping of conductors
• 4 seats for conductors for each polarity
• terminal suitable for KNX bus cable with single-wire
conductors and diameter between 0.6 and 0.8 mm
• recommended wire stripping approx. 5 mm
• color codification: red = + (positive) bus conductor,
black = - (negative) bus conductor
!
Warning! In order to supply the KNX bus lines use
only a KNX bus power supply (e.g. ekinex EK-AB1-
TP or EK-AG1-TP). The use of other power supplies
can compromise the communication and damage
the devices connected to the bus.