7. Adjuster speeds up from the left to the right.
8. There are 2 timers in the machine, which record the single operation time and single stop time
separately.
Note: The minimum speed shall be over 100; The maximum speed shall be under 300.
9. Press "STOP" to end the test. (Red light is on) Motor is off power; Fetch the test samples and
record the result.
10. The tachometer is correctly described below:
The data displays after pressing SET key:
0310 --- 0060 --- 1.000 ---- decimal point beating ---- 3721
The password of this machine is :3721; Enter the password before modifying the parameters.
VI. Precautions and Maintenance
1. Please keep the machine clean before and after use, otherwise the motor will be effected if the
machine is with dust.
2. Please spray a layer of oil to resist the rust.
3. If the motor has a special sound ( temperature is over 70℃) in working, it should be stopped
immediately and be fully examined. The bearing should be replaced if it is found to be
damaged; The seat fasteners should be reset if it is found to be loose; Ca-based oil should be
lubricated if it is found to be lack of oil.
4. It is prohibited to disassemble the electrical components, which will damage the electrical
control circuit and effect the performance of this machine.
5. The machine shall be installed away with flammable and explosive materials.
Add: 3
rd
Industrial Area, Jingshan Village, Chashan Town, Dongguan
- 4 -
Tel:0769-33365786 Fax:0769-23051695