NOTES:
1. If any of the menu items are left unattended
for 3 minutes, the menu will time out and
automatically save all settings and return to
automatic operation.
2. If a sensor fault is detected the controller will
display which sensor and what the fault is.
3. Should power be interrupted for any reason,
the controller will resume normal operation
when power is restored, all information will
have been kept for 10 days.
4. If the controller has stopped pumping and is
displaying
a
higher
expected it may be caused by a pump which
is failing to prime, check the pump and if
necessary prime the pump as per the pump
manufacturers' instructions then reset the
controller by turning it off/on.
WARRANTY
• This range of product is covered by a limited 3 year warranty against component failure or
faulty workmanship from the date of installation.
• Faulty units should be returned in the first instance to the dealer from which the unit was
purchased.
• Damage to the unit due to misuse, power surges, lightning strikes or installation that is not in
accordance with the manufacturer's instruction may void the warranty.
• Warranty does not include on-site labour or travel costs to or from installation site.
If the power cord is damaged, do not use the controller; return the unit to the supplier for repair.
(To be retained by the customer)
CUSTOMER RECORD
DEALER/INSTALLER NAME
SERIAL NUMBER
DATE INSTALLED
For service assistance email [email protected]
Dontek Electronics Pty Ltd
www.dontek.com.au
PO Box 239, Bayswater VIC 3153 Australia
Phone: +613 9762 8800 Email: [email protected]
AQUAHEAT H5TC v1.0
temperature
than
5. Maximum combined rated output load for the
240V socket(s) is 9.98 Amps / 2395 Watts.
6. Degree of protection against moisture: IP33.
7. Smaller bodies of water running a higher
temperature limit (i.e. spa) the sample time
should be set shorter than larger bodies of
water that run lower temperature limits (i.e.
pool). If the pump runs for 3 minutes and
stops frequently, then increase the sample
time as the body of water is not losing much
heat.
8. On power-up there is a counter next to the
revision number that displays the number of
interrupted heater cool-down cycles. This
number cannot be reset.
9. A voltage free switch can be wired into the
righthand Red plug which will force heating
out of demand times.
4