PRECAUTIONS, RESTRICTIONS AND WARNINGS
Sensibility to predictable environmental conditions in regular use conditions
The equipment has been planned not to be sensitive to interference such as magnetic fields,
external electrical factors, electrostatic discharge, pressure or variance of pressure, provided that
the equipment is installed, maintained, clean, preserved, transported and operated as per this
instruction for use.
Precautions and warnings "during the use" of equipment
- The equipment should only be operated by duly enabled and trained technicians (Dental Surgeons,
Capacitated Professionals).
- Before the first use and/or after long interruptions from work such as vacations, clean and
disinfect the equipment.
- If any maintenance should be required, only use services of the Dabi Atlante Authorized Technical
Assistance.
- Owing to its delicate components, this handpiece must not be dropped or undergo impacts.
- Although this equipment has been planned in accordance with the standards of electromagnetic
compatibility, it can, in very extreme conditions, cause interference with other equipment. Do not
use this equipment together with other devices very sensitive to interference or with devices which
create high electromagnetic disturbance.
- Do not expose the plastic parts to contact with chemical substances, use in the routines of dental
treatment, such as: acids, mercury, acrylic liquids, amalgams, etc.
- The use of pneumatic or electric tools to perform any type of recording on handpieces, could lead
to damage to the surface treatment of the product, causing the loss of warranty.
Dabi Atlante shall not be responsible for:
- Use of the equipment differing from that for which it is intended.
- Damages caused to the equipment, the professional and/or the patient by the incorrect installation
and erroneous procedures of maintenance, differing from those described in these Instructions for
use which come with the equipment or by the incorrect operation of it.
Precautions and warnings "after" the use of equipment
- Always maintain the equipment clean for the next operation.
- Do not modify any part of the equipment. Do not disconnect the cable or other connections
without need.
- After using the equipment, clean and disinfect all the parts which may be in contact with the patient.
Precautions in case of alteration in the functioning of equipment
- If the equipment has any abnormality, check if the problem is related to any item listed in the topic of
unforeseen events (failures, causes and solutions). If it is not possible to resolve the problem, contact
your representative (Dabi Atlante).
Precautions to be adopted against foreseeable or uncommon risks, related to
the deactivation and abandoning of equipment
In order to avoid environmental contamination or undue use of the Equipment after it has become
useless, it should be discarded in the suitable place (as per the local legislation of the country).
- Pay attention to the local legislation of the country for the conditions of installation and disposal
of residue.