7. operator proGrammInG
7.1. BasIC proGrammInG
To go into the BASIc prOGrAmmInG mOde, press the key "f". On the left display you will see the name of the function, which
is to be programmed and on the right display you will see current value of this function. The value can be changed by pressing
keys "+" or "–". If you press the key "f" again, you will see the name of the next function on the display and you will be able to
program it and so on. After you have programmed all the functions you can exit the programming mode by pressing the key "f".
display
programming of pause time before automatic closing: 1 — 10 s, 2 — 20 s, 3 — 30 s, 4 — 60 s,
A
C
first leaf closing delay: 1 — 1 s, 2 — 5 s, 3 — 10 s, 4 — 15 s, 5 — 20 s, 6 — 25 s, 7 — 30 s, 8 — 35 s, 9 — 40 s
E
F
00
7.2. adVanCed proGrammInG
To go into AdVAnced prOGrAmmInG mode, press the key "f" and holding it down, press the key "+". you will see the name of
the function to be programmed. On the right display you will see the current value of the function, which can be changed by pressing
the keys "+" or "-". If you press the key "f" repeatedly, you will see the name of the next function on the display and you will be able
to program it. After all the functions have been programmed, you can exit the programming mode by pressing the key "f".
display
H
L
Indicator light: 1 — 10 s, 2 — 20 s, 3 — 30 s,4 — 60 s, 5 — 90 s, 6 — 120 s, 7 — 180 s, 8 — 360 s, 9 — 420 s
0
If the function is on and the pause time is preset than the gate closes as soon as the safety devices
P
S
If the function is on the gate closes/opens only if a corresponding button is hold down У — on; n — off
If the function is on the opening gate can be stopped only by the limit switches, the closing gate
II
7.3. operatIon tIme proGrammInG
In order to program the motor operation time, close the gate and couple the operators (if there is a rabbet, program a leaf
opening/closing delay). Then enter the basic programming mode, select function "f", press and release "+." The leaves will begin
to open. After they reach the limit switches, the leaves will stop. At this moment give a control command. programming is done.
press "f" again to leave the basic programming mode. When the next control command is given the leaves will start moving in
accordance with the programmed operation mode.
5 — 90 s, 6 — 120 s, 7 — 180 s, 8 — 360 s, 9 — 420 s
programming of the first motor force: b1 — minimal; b9 — maximal
programming of the second motor force: С1 — minimal; С9 — maximal
Second leaf opening delay: 1 — 1 s, 2 — 2 s, 3 — 3 s, 4 — 4 s, 5 — 5 s
programming of the motor operation time
counter of the cycles (one division — 100 cycles)
maximal force at the starting time: У — on; n — off
pre-activation of a signal lamp (5 s): У — on; n — off
Safety devices: У — immediate reverse; n — reverse after the opening is cleared
are actuated У — on; n — off
can be stopped in a usual way У — on; n — off
function