6. uncontrolled moVement protectIon
DCUH-1 control unit has an uncontrolled movement protection system. The system is activated by the emergency stop signal
event during operation of the dock leveler or by power outage. To resume operation of the dock leveler, press the lift button.
7. tecHnIcal data
Supply voltage 380 V 50 Hz.
Control voltage 24 V
Maximal load of hydraulic aggregate 1 kW.
Vertical installation on the wall at a height of 1 m –1.5 m.
Operational temperature from –10° C up to +55° С
Dimensions mm 280×180×130
Protection rate IP 65
This control unit does not need programming. After all necessary connections have been completed, the control unit is ready
for operation.
Control unit works only with DC coils.
6
ConneCtIon – General InstruCtIons