DoorHan DCUT-1 Руководство пользователя - Страница 2

Просмотреть онлайн или скачать pdf Руководство пользователя для Блок управления DoorHan DCUT-1. DoorHan DCUT-1 8 страниц. Telescopic lip dock leveller
Также для DoorHan DCUT-1: Оригинальные инструкции по установке (8 страниц), Руководство (8 страниц)

DoorHan DCUT-1 Руководство пользователя

1. GENERAL INFORMATION

DCUT-1 control unit operates electro-hydraulic dock leveler
with telescopic lip of DS/DSI/DSIM series.
The unit is equipped with an uncontrolled movement pro-
tection system, which is activated if the dock leveler was
halted in the event of a potential emergency or if power
supply failed.
Table 1.1. Control units options
Options
Automatic return to stored position by pressing the P button
Supply voltage, 380-415 V / 50-60 Hz
External traffic light
Internal traffic light
Dock leveler lighting
Leveler locking when door is closed (interlock)
Door locking when leveler is open (interlock)
Connection of additional safety devices
Service indicator
Menu screen (LCD display)
Door control
Inflatable dock shelter control
Table 1.2. Control unit specifications
Parameters
Supply voltage
Control voltage
Max. power of the hydraulic station
Operating temperature
Dimensions (W × H × D)
Protection class

2. SAFETY RULES

WARNING!
Carefully follow all the instructions specified herein. Failure to do so could cause equipment damage and/or personal
injury!
 Use the control unit only for its intended purpose, any
other use is prohibited.
 The manufacturer assumes no liability for damage or
injury to persons or property which occur as a result of
failure to observe safety rules specified herein or incor-
rect use of the control panel.
 Only trained personnel should install, operate or service
this equipment.
2
This control unit does not require programming. After all
the necessary connections, it is ready for operation.
The control unit works with DC coils only.
DCUT-1
Value
380-415 V / 50-60 Hz
24 VDC
1,5 kW
-20...+50 °С
195 × 355 × 165 mm
IP54
 Correct operation of the control unit can only be guar-
anteed if the supply voltage complies with the specified
in the instructions.
 Prior to first actuation of the control unit, make sure
that all electrical connections are securely fastened and
insulated, safety devices are installed and ready for use.