Canon PIXMA MX340 Series Упрощенное руководство по обслуживанию - Страница 9

Просмотреть онлайн или скачать pdf Упрощенное руководство по обслуживанию для Принтер "все в одном Canon PIXMA MX340 Series. Canon PIXMA MX340 Series 35 страниц. Cartridge reset
Также для Canon PIXMA MX340 Series: Руководство по установке (17 страниц), Руководство по установке (11 страниц), Руководство по настройке сети (26 страниц), Брошюра (2 страниц), Руководство (8 страниц), Руководство (10 страниц), Устранение неполадок при настройке сети (13 страниц), Руководство по установке сети (16 страниц), Руководство по подключению (11 страниц), Руководство (4 страниц)

Canon PIXMA MX340 Series Упрощенное руководство по обслуживанию
Error
TX /
code
RX
##109 TX
After DCS transmission, a signal other than DIS,
DTC, FTT, CFR, or CRP has been received, and
re-transmission of the procedure signal has been
attempted the specified number of times but failed.
##111 TX /
Memory error
RX
##114 RX
RTN has been received.
##200 RX
A carrier has not been detected for 5 seconds
during image reception.
##201 TX /
DCN has been received in a method other than the
RX
binary procedure.
##204 TX
DTC has been received even when there is no
sending data.
##220 TX /
System error (main program hang-up)
RX
##224 TX /
An error has occurred in the procedure signal in G3
RX
transmission.
##226 TX /
The stack pointer has shifted from the RAM area.
RX
##229 RX
The recording area has been locked for 1 minute.
##232 TX
The encoder control unit has malfunctioned.
##237 RX
The decoder control unit has malfunctioned.
##238 RX
The print control unit has malfunctioned.
##261 TX /
A system error has occurred between the modem
RX
and the system control board.
##280 TX
Re-transmission of the procedure signal has been
attempted the specified number of times, but failed.
##281 TX
Re-transmission of the procedure signal has been
attempted the specified number of times, but failed.
##282 TX
Re-transmission of the procedure signal has been
attempted the specified number of times, but failed.
##283 TX
Re-transmission of the procedure signal has been
attempted the specified number of times, but failed.
##284 TX
After TCF transmission, DCN has been received.
##285 TX
After EOP transmission, DCN has been received.
##286 TX
After EOM transmission, DCN has been received.
##287 TX
After MPS transmission, DCN has been received.
##288 TX
After EOP transmission, a signal other than PIN,
PIP, MCF, RTP, RTN has been received.
##289 TX
After EOM transmission, a signal other than PIN,
PIP, MCF, RTP, RTN has been received.
##290 TX
After MPS transmission, a signal other than PIN,
PIP, MCF, RTP, RTN has been received.
Meaning
(8/37)
Solution
(parts that are likely to be faulty)
- Eliminate all the data, and register
them again.
- Increase the transmission level of the
sending machine.
- Increase the transmission level of the
sending machine.
- Set the other machine ready for
reception.
- Turn the machine off, and turn it on
again.
- NCU board
- Turn the machine off, and turn it on
again.
- After the area is unlocked, print the
recorded image.
- NCU board
- NCU board
- NCU board
- Logic board
- NCU board
- Logic board
- Try a higher transmission level.
- Try a higher transmission level.
- Try a higher transmission level.
- Try a higher transmission level.
- Set the receiving machine ready for
reception.
- Re-send the fax.
- Re-send the fax.
- Re-send the fax.