Air Dimensions Incorporated Dia-Vac R Series Руководство по эксплуатации - Страница 4
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Водяной насос Air Dimensions Incorporated Dia-Vac R Series. Air Dimensions Incorporated Dia-Vac R Series 11 страниц. Elevated/extended pump with explosion proof motor
Minimum Performance Requirements
Eccentric
R27x
R25x
R22x
R20x
R18x
R15x
R12x
R10x
R08x
R06x
NOTE: Check each separately, one or the other port must be open during this test. Use 0‐100 PSI pressure
gauge and 0‐30 inch Hg vacuum gauge, (or mercury manometer.)
Troubleshooting
This section lists common problems that occur, possible causes and the most common fixes. If the problem
persists, the pump may require inspection at the ADI facility. To have your pump inspected and repaired
at the ADI facility please follow the instructions on the ADI website located at
http://www.airdimensions.com/service/rma/.
Standard Product 60Hz
Max Press
PSIG
Minimum
60
52
46
36
27
17
13
8
7
4
(50 Hz)
Open Flow
LPM
Minimum
27
(22)
25
(21)
26
(22)
22
(18)
19
(16)
17
(14)
14
(12)
12
(10)
11
(9)
8
(7)
4
Ult Vac
In Hg
Minimum
24
23.5
23
21.5
20
17
15
13
11
7