Astralpool VICTORIA DUAL SPEED Руководство - Страница 7

Просмотреть онлайн или скачать pdf Руководство для Насос для плавательного бассейна Astralpool VICTORIA DUAL SPEED. Astralpool VICTORIA DUAL SPEED 20 страниц. Self-priming pump for swimming pool

To enter into the programming mode, the PROG/OK button will have to be pressed for more than 3 seconds. The Season
selection screen will appear.
In all the screens the PROG/OK button should be pressed to confirm the selection.
To exit the programming, the PROG/OK button will have to be pressed for more tan 3 seconds.
PROGRAM ERASING
The digital timer allows the user to erase the programs by full days.
To erase a complete day, the ERASE button must be pressed into the Hour or Speed programming screens.
SPECIAL PROGRAMS: RINSE AND BACKWASH
The digital timer has two specific programs for the filter maintenance: RINSE and BACKWASH.
To run these programs, the timer must be in MAN mode. In this way, the process to run these programs must be the
following:
1st: Enter to the MAN mode: Press the MAN/AUTO button until reach the MAN mode (appears in screen).
2nd: Press the RINSE or BACKWASH button to start the program.
To stop the program, it is only needed to press the ERASE button in any moment.
SPECIAL PROGRAMS PROGRAMMING:
To program the two specific programs for the filter maintenance, the following process must be followed:
RINSE PROGRAM PROGRAMMING:
Initial screen
The texts PROG and RINSE blink in the screen
Speed selection (Eco or Turbo)
Preset values: ECO mode for 30 seconds.
Victoria Dual Speed
- ASTRALPOOL
PROG/OK + RINSE
STOP/ECO/TURBO
Initial screen
TIME
Time selection (seg.)
To confirm: PROG / OK
7