inrush current
Measure inrush current of AC conductors
carrying up to 1000 amperes�
1�
Turn the Rotary Switch to the
60/600 or
depending on the amperage of
the conductor under test�
2�
Press reL/inruSH for two or
more seconds to switch to inruSH
current mode� ---- displays while the
inrush current is being detected�
3�
Using one hand, press Trigger to
open Current Clamp and insert
conductor inside the jaws�
ac/Dc Voltage Measurement
Measure AC conductors carrying
up to 750 VAC, 40-400 Hz�
Measure DC conductors
carrying up to 1000 VDC�
WarninG! Use caution when working
near voltages above 30 VAC rms, 42
VAC peak, or 60 VDC� Voltages this
high present a risk of electric shock�
1�
Plug black test lead into cOM Jack�
Plug red test lead into input Jack�
2�
Turn Rotary Switch to the
m
position, depending on the
voltage of the conductor under test�
Item 64017
1000 position,
or
For technical questions, please call 1-888-866-5797.
4�
Read measured inrush current
on the Display� The current is
only measured once and the
reading is held on the Display�
5�
When testing is complete, turn
Rotary Switch to OFF, and store Meter�
note: If the Display shows OL while in
manual range mode, the measurement
has exceeded the selected range� A
higher range should be selected�
3�
Press Func button to choose
between AC and DC voltage�
4�
Carefully touch exposed
conductors with tips of probes�
5�
Read measured voltage on the Display�
6�
When testing is complete, turn
Rotary Switch to OFF, remove
Test Leads and store with Meter�
note: If voltage is too high, Meter will beep�