Trouble Shooting
Fault
Description
Fail 2
Unable to See Distributor
Fail 4
Unit Number not
Programmed
No Ring in
Calling at door station but no
Unit
ring in unit
Poor Video
Poor Quality or No Video on
monitors
Calls but
Able to call but drops out
Drops Out
after answering
No lock
No lock release from ANY
Release
method
No Lock
Public Password does not
Release
work
No Lock
Unlock Button does not work
Release
on internal station
No Lock
Swipe Card/Fob does not
Release
allow access
Rectification
1) Fault with building cabling or
equipment - contact service agent
1) Ensure correct number is entered
2) Fault with programing – contact
service agent
1) Fault with building cabling or
equipment - contact service agent
1) 100 Ohm resistor not installed on
last distributor between VF+ and
VF-
2) Poor VF+ or VF- (Green/Green
White) connection in system
3) Fault with internal station
connection or device
1) Fault With Internal station or
wiring – contact service agent
2) If System states "unlock" and the
door does not unlock – fault with
door lock device – contact service
agent
1) If system advises WRONG
PASSWORD, incorrect password
used.
2) If System does not allow public
password entry – function is not
programmed.
1) Internal Station faulty
2) System Fault – contact service
agent
3) If swipe card does not read and
others do – faulty card
4) If reader does not read any cards –
equipment fault – contact service
agent
5) If FAIL or 3 beeps are given when
presenting fob – fob not
programmed.
7