Flying Industry Development C-4L Краткое руководство - Страница 2

Просмотреть онлайн или скачать pdf Краткое руководство для Пульт дистанционного управления Flying Industry Development C-4L. Flying Industry Development C-4L 2 страницы. Rf wireless remote control radio controller / transmitter & receiver

Setting control mode Momentary + Toggle: Connect Jumper-1 and Jumper-2.
Control mode Momentary (Channel 1, 2): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay 1 (connect B and C, disconnect A and B)
Release button 1: Turn off relay 1 (disconnect B and C, connect A and B)
Press and hold button 2: Turn on relay 2 (connect B and C, disconnect A and B)
Release button 2: Turn off relay 2 (disconnect B and C, connect A and B)
Control mode Toggle (Channel 3, 4): Press -> On; Press again -> Off.
Press button 3: Turn on relay 3 (connect B and C, disconnect A and B)
Press button 3 again: Turn off relay 3 (disconnect B and C, connect A and B)
Press button 4: Turn on relay 4 (connect B and C, disconnect A and B)
Press button 4 again: Turn off relay 4 (disconnect B and C, connect A and B)
We have learned remote control to the receiver. If you don't want the receiver to work with the remote control, you can delete all codes of remote
controls, which are stored in the receiver.
Operation: Press and hold the button of receiver until signal LED flashes slowly; release the button, LED keeps slow flash. That means all stored
codes have been deleted successfully.
Learning the button of remote control:
1) Press the button of receiver; signal LED on the receiver keeps shining. The receiver enters into status of LEARNING.
2) Press any one button on remote control. If signal LED flashes quickly 15 times and turns off, it means learning is successful.
3) When receiver is in the status of LEARNING, press again the button of receiver, signal LED turns off, learning process will be discontinued.
4) The receiver can learn several remote controls with different codes.
DC0~28V / AC110~240V
+
Power Supply: DC12V
_
Lamp 4
Lamp 3
A
B
C
C
Lamp 2
B
A
C
Lamp 1
B
A
+
Power Supply
_
A, B=Normally Closed; B, C=Normally Open.
Application: For DC12V motor or lamp
M
Motor 4
M
Motor 3
A
B
C
M
C
Motor 2
B
A
M
C
Motor 1
B
A
+
_
SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com
Application Circuit
A
B
C
Relay 4
Relay 3
Relay 1
Relay 2
Antenna
RF module
A
B
C
Relay 4
Relay 3
Relay 1
Relay 2
Antenna
RF module
LED
IC
Button
LED
IC
Button