Coilhose Pneumatics IN-LINE 50038 Инструкции по установке и эксплуатации - Страница 2

Просмотреть онлайн или скачать pdf Инструкции по установке и эксплуатации для Системы смазки Coilhose Pneumatics IN-LINE 50038. Coilhose Pneumatics IN-LINE 50038 2 страницы.

Cleaning:
Coilhose In-Line Lubricators will provide long periods of uninterrupted service, provided the air and the oil supply are
kept clean. Periodic cleaning is recommended.
To remove and clean the lubricator:
1. Depressurize line and disconnect the lubricator from the air supply.
2. Slowly remove oil fill cap to relieve pressure in oil reservoir and then drain the oil. Caution: If pressure is released too
quickly, oil may spray from reservoir.
3. Remove lubricator from air tool.
4. "Back flush" lubricator to blow out any dirt or residue.
5. Clean lubricator with warm water and household detergent or mild commercial-grade solvent.
6. Make sure all moisture is removed by thoroughly blowing out the unit with compressed air.
7. Follow "Installation and Filling" instructions below to reinstall lubricator.
Installation and Filling:
1. Apply a small amount of thread sealant compound to the lubricator male threads (B).
2. Hand tighten male connector into female inlet of the air tool.
NOTE: Adding a 6" snubber (whip hose) between the air tool and lubricator will provide a safer and longer lasting
installation.
3. Hand tighten male air supply outlet of lubricator into female inlet of the lubricator (C).
4. Wrench tighten both connections until air tight seals are formed.
5. Remove oil fill cap (A) and fill reservoir with lubricant, leaving a small amount of space for air.
6. Replace and tighten oil fill cap until air tight.
7. Connect air supply.
8. Activate air tool several times to set needle valve into action.
Caution: Do not use synthetic oil.
Detergent oil, antifreeze fluid, and machine oil heavier than SAE # 40 (S.U.V. 800 S.E.C. at 100° F) should not be used.
For applications with temperatures above 40° F, we recommend the use of Coilhose non-detergent ATL rust-proofing
lubricant; for applications with temperatures between - 40° F and 40° F, we recommend the use of Coilhose ATLW
lubricant.
Caution: Do not exceed 150 PSI Inlet pressure.
East/Central: 19 Kimberly Road • East Brunswick, NJ 08816 • Phone: 732-390-8480 / Fax: 732-390-9693
West: 1730 NE Miller Street • McMinnville, OR 97128 • Phone: 503-434-5964 / Fax: 503-472-1989