Before connecting a heating stove to an existing chimney, in addition to complying with that described above,
make sure there are no
openings or cracks where air
could enter and cause a
temperature decrease
affecting the draught.
Also make sure there are no
hindrances caused by foreign
bodies or a build-up of soot.
The first connection section
leaving
the stove should be vertical,
whereas the flue connection
to the chimney (which goes
to the chimney cap) must
only enter by a few cm, so as
not to reduce the cross
section of the flue.
If the flue is not perpendicular
to the chimney it is advisable to make the connection with special steel fittings that allow a maximum slope of
45° .
If the walls and ceiling are made of flammable materials, the parts in contact with the flue must be suitably
insulated. All connection joints must be carefully sealed, in particular where the connection enters the flue.
If there are several heating stoves in the same home, each must have its own flue. It is inadvisable to make
openings in the flue for other appliances, since the draught could be negatively affected.
According to Standard UNI 7429, the chimney cap must meet several requirements; above all, it must have a
useful outlet cross section at least double that of the flue. It is also advisable to install an "antiwind" cap that
guarantees fume exhaust even in the presence of strong horizontal winds.
YES
NO
3– STOVE USE
3.1 Introduction
Never leave children unsupervised in the vicinity of the stove; the risk of burns caused by the hot parts is very
high.
Also:
-
-
-
3.2 Startup
Do not light the heating stove without water inside it; the irregular stresses could cause breakage of the
boiler.
When lighting the stove the first time, bad odours may be created, therefore air the room thoroughly.
Light the heating stove with a low flame and allow it operate for about 30 minutes with the oven door open and
the damper in position Z. Then, with the oven door still open, shift the damper to position A and allow the
heating stove to operate for another 30 minutes.
After lighting the heating stove the first time it must operate for many hours with a low flame (air control on ash
door open 30%). The heat can then be increased a little at a time, so that the stove expands slowly and the
paint and putty dry.
NO
never use the heating stove with the ash door and/or fire door open;
do not store firelighters or other easily combustible materials in the vicinity of the stove;
do not try to move or lift the stove by the handles.