INSTALLATION GUIDE
STEP 1: ROD PREPARATION
Ensure Rod tubes are cut to the
correct lengths.
Insert Mid Connectors (the side
with the shoulder) into one end
of either tube and Threaded
Connector into the opposite end
of either tube.
Crimp ends to secure
connectors in place.
Thread D-Bolt onto rod ends
with 5mm of clearance between
D-Bolt and shoulder.
CALCULATING ROD LENGTHS:
Top Tube Length
(D) - (H) - 240mm = Tube Length
Door Height (D),
minus Handle Height (H),
minus 240mm (lockbody)
Bottom Tube Length =
(H) - 300mm = Tube Length
Handle Height (H),
minus 300mm (lockbody)
DS2800 I
LIFT TO LOCK
MORTICE LOCKBODY
STEP 2: MID GUIDE INSTALLATION
The mid guide has a short leg (a),
and a long leg (b).
Fit both the top and the bottom
Mid Guide
Surface Mounted
Ensure shorter
leg (a) is against
the inside edge
of the front face
of the extrusion.
Line up with the
drill holes and
fix in place with
8G x 1/2"
Countersink
Screws.
Tab Mounted
Ensure longer
leg (b) is against
the inside edge
of the front face
of the extrusion.
Line up with the
drill holes and
fix in place with
8G x 1/2"
Countersink
Screws.