Canon 7215 - LV XGA LCD Projector Технические характеристики - Страница 15

Просмотреть онлайн или скачать pdf Технические характеристики для Проектор Canon 7215 - LV XGA LCD Projector. Canon 7215 - LV XGA LCD Projector 47 страниц. Mounting hanger for low ceilings
Также для Canon 7215 - LV XGA LCD Projector: Технические характеристики (22 страниц), (Японский) Руководство по сборке и установке (8 страниц)

Canon 7215 - LV XGA LCD Projector Технические характеристики
EXPAND SERIAL COMMAD FUNCTIONAL SPECIFICATION for LV-5210/7215/7210
8.4 IMAGE Command
8.4.1

CF_BRIGHT Command

COMMAND
"CF_BRIGHT_%1" [CR]
"000-063"------ Directly select the Bright Setting Value
%1
"UP"---------------- Bright setting value +1
"DN"---------------- Bright setting value -1
Set the User control Bright Value
The value set by the command will not be saved to the projector. Therefore,
Details
when ALL OFF the projector, the value will return to the original setting.
(For STANDBYMODE, this value stays.) Only valid when it is in the usual
Power ON State.
Acceptable
Response
Unacceptable
8.4.2
CF_CONTCOMMAND
COMMAND
"CF_CONT_%1" [CR]
"000-063"------ Directly select for conntrast setting value
%1
"UP"---------------- Contrast setting value
"DN"---------------- Contrast setting value-1
Set the user Control contrast value.
The value set by this command will not be saved to the projector. Therefore,
Details
when ALL OFF the projector, the value will return to the original setting
(For STANDBYMODE, this value stays.) Only valid when it is in the usual
Power ON status.)
Acceptable
Response
Unacceptable
8.4.3
CF_COLORCOMMAND
COMMAND
"CF_COLOR_%1" [CR]
"000-063"------ Directly Color setting value
%1
"UP"---------------- Color setting value+1
"DN"---------------- Color setting value-1
Set the user Control Color value.
The value set by this command will not be saved to the projector.
Details
Therefore, when ALL OFF the projector, the value will return to the original
setting. (For STANDBYMODE, this value stays.) Only valid when it is in
the usual Power On state.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
Page