Configuration
5
Configuration
Before starting
►
NOTICE
Before switching on, make sure that the device was stored at the specified ambi-
ent temperature (-20 ... +55 °C) for at least 30 minutes.
Parameters of the module can be read, edited and saved with "M110 Configurator" soft-
ware (on the CD included). The full list of parameters is shown in the Table 5.1.
To control the module via Modbus network refer section 6.3 "Modbus addressing"
The module should be configured first before operating in RS485 network.
Proceed as follows:
–
–
–
–
–
If the factory settings of the module have not been changed, the connection to the mod-
ule is automatically established, the module automatically recognized, its configuration
parameters read out and an appropriate configuration mask open.
If it does not happen, parameters of the configurator should be changed.
Table 5.1 Configuration parameters
Name
dev
bPS
LEn
PrtY
Sbit
akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de
install the configuration software "M110 Configurator" on the PC
connect the device to the USB interface of the PC over USB/RS485 adapter (not
included)
connect the power supply to the terminals 24V / 0V
turn on the device
start the M110 Configurator
Parameter
Device
Firmware version
ver
Baud rate, kbit/s
Data bits *
Parity *
Stop bits *
Valid value
Basic parameters
Up to 8 characters
Up to 8 characters
Network parameters
0
1
2
3
4
5
6
7
8
0
1
0
1
2
0
1
Meaning
Default
MU110-8I
manufacturer
2.4
4.8
9.6
14.4
19.2
9.6
28.8
38.4
57.6
115.2
7
8
8
none
even
none
odd
1
1
2
8