Dormakaba MUTO Premium Инструкции по монтажу - Страница 3

Просмотреть онлайн или скачать pdf Инструкции по монтажу для Внутренняя отделка Dormakaba MUTO Premium. Dormakaba MUTO Premium 8 страниц. Integrated locking device

Dormakaba MUTO Premium Инструкции по монтажу
dormakaba Montageanleitung
Mounting instructions
3.5
Setting options for the locking device
DIP switch 1 = OFF Sequential control active
Sequential control active = The locking device
can only be activated with the door in closed
position.
DIP switch 1 = ON Sequential control inactive
Sequential control inactive = The locking
device can be activated regardless of door
position.
Important: Carry a hand-held transmitter.
DIP switch 2 = OFF Audible warning active
DIP switch 2 = ON Audible warning inactive
3.6

Device LED feedback

Various locking states are indicated by the device LED
flashing:
The device LED flashing
code
Slow flashing
Rapid flashing
Once long, x times short
(depending on error type)
2x long, 1x short
MUTO Comfort / Premium
ON 1 2
Meaning
Teach-in mode
Reset
Error.
Internal defect.
The device must be
replaced.
Test after power ON
WN 058855 45532
3.7
Acoustic feedback/Warning thresholds
A low or empty battery is indicated by beeping when
DIP switch 2 = OFF "Audible warning active" is set.
Warning threshold 1:
2 beeps = battery replacement is recommended.
Warning threshold 2:
6 beeps = battery replacement is required.
The locking device can only unlock and then becomes
inoperative.
Removing the batteries resets the meter.
Therefore we recommend only removing the batteries
to replace them. Otherwise the meter will not reflect
the true battery charge status.
3.8
Notes on radio operation
The frequencies used by the locking device are also
used by other devices, so interference cannot be
excluded. Structural conditions and environmental
influences such as humidity impact the transmitter's
range.
Duty cycle
The duty cycle describes a legally regulated limitation
of the transmission time of devices in the 868 MHz
range.
The maximum transmission time is 36 seconds/hour.
When this limit is reached, all further transmissions
are inhibited (see Chapter 7).
3.9
Behavior after voltage recovery
A test is performed after the batteries are inserted.
If an error is detected, this is indicated by the device
LED flashing (see Chapter 3.6). This is repeated
continuously and the locking device does not function.
Product description
2020-03
3